Search results for "β-Adrenoceptor antagonists"

showing 2 items of 2 documents

Analysis of basic drugs by liquid chromatography with environmentally friendly mobile phases in pharmaceutical formulations

2017

Abstract Basic drugs are positively charged in the usual working pH (2–8) in reversed-phase liquid chromatography. This gives rise to a strong association with the residual ionized silanols in conventional silica-based stationary phases, which is translated in poor peak shape and high consumption of organic solvent to get appropriate retention times. Micellar mobile phases containing surfactants give rise to modified stationary phases, where silanols are masked, improving the peak shape. However, mobile phases containing the anionic surfactant sodium dodecyl sulfate (SDS) require a small amount of organic solvent to conveniently decrease the retention of cationic analytes. An alternative is…

AnalyteMethod validation01 natural sciencesAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPulmonary surfactantlawmedicineSample preparationSodium dodecyl sulfateBrij-35β-Adrenoceptor antagonistsSodium dodecyl sulfateSpectroscopyFiltrationChromatography010405 organic chemistryChemistry010401 analytical chemistryCationic polymerizationEnvironmentally friendly0104 chemical sciencesOxprenololPharmaceutical formulationsmedicine.drug
researchProduct

Effect of buffer nature and concentration on the chromatographic performance of basic compounds in the absence and presence of 1-hexyl-3-methylimidaz…

2019

Abstract In reversed-phase liquid chromatography, the performance for basic compounds is affected by the interaction of the protonated (cationic) species with the anionic free silanols on the alkyl-bonded stationary phases. Using aqueous-organic mobile phases in the absence of additives, the retention may be too high, and the peaks be broad and asymmetric. The performance is improved by addition to the mobile phase of ionic liquids, from which 1-hexyl-3-methylimidazolium chloride ([C6MIm][Cl]) has especially good characteristics. A recent report has also revealed that the use of the phosphate system as buffer, at varying concentration and pH, may have a significant role in the chromatograph…

buffer systemsAcetonitrilesAdrenergic beta-AntagonistsIonic LiquidsProtonationBuffers010402 general chemistry01 natural sciencesBiochemistryChlorideAnalytical Chemistryionic liquidschemistry.chemical_compoundreversed-phase liquid chromatographyBoratesmedicineFormateβ-Adrenoceptor antagonistsChromatography High Pressure LiquidChromatography Reverse-PhaseChromatography010401 analytical chemistryOrganic ChemistryCationic polymerizationImidazolesWatersilanol effectGeneral MedicineReversed-phase chromatographyHydrogen-Ion ConcentrationPhosphate0104 chemical sciencesSilanolchemistryIonic liquidSolventsmedicine.drug
researchProduct